{"id":17298,"date":"2023-06-27T14:11:23","date_gmt":"2023-06-27T12:11:23","guid":{"rendered":"https:\/\/www.klinger-kempchen.de\/?page_id=17298"},"modified":"2024-03-11T11:49:12","modified_gmt":"2024-03-11T10:49:12","slug":"designing-sealed-connections","status":"publish","type":"page","link":"https:\/\/www.klinger-kempchen.de\/en\/engineering\/engineering-services\/designing-sealed-connections\/","title":{"rendered":"Designing sealed connections"},"content":{"rendered":"\n<h1 class=\"wp-block-heading\"><strong>DESIGNING SEALED CONNECTIONS AND SPECIAL GASKETS<\/strong><\/h1>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<h2 class=\"wp-block-heading\">Experience and knowledge of seals and sealing materials<\/h2>\n\n\n\n<p>The designing, construction, calculation and specifications of gaskets and sealed connections require a great deal of experience and knowledge about how gaskets and sealing materials behave under various operating conditions. The mere application of well-known guidelines such as ASME, DIN EN 13445 or AD 2000 and purely examining the gasket or sealed connection using gasket parameters such as DIN EN 13555 say nothing about the leak tightness of a flange joint in the relevant installation or operating conditions.<\/p>\n\n\n\n<p>We can offer you a complete service, starting with a preselection of suitable materials and suitable types of gaskets, to the design and specifications of the required components, right up to coordinating with the corresponding third party &nbsp;organisation (notified body) or ASME inspection agencies.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns are-vertically-aligned-center has-white-background-color has-background is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<h3 class=\"wp-block-heading h2\">Design criterion seal <br>design parameter gasket<\/h3>\n\n\n\n<p>The gasket parameters determined using standardised test rigs, especially the results from leakage tests, frequently serve as a basis for selecting the gasket. However, an integral examination and design must be carried out to produce tight flange joints.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"960\" height=\"600\" src=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/04\/r1-konstruktion-01-klinger-kempchen.jpg\" alt=\"Konstruktion 3\" class=\"wp-image-16050\" srcset=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/04\/r1-konstruktion-01-klinger-kempchen.jpg 960w, https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/04\/r1-konstruktion-01-klinger-kempchen-768x480.jpg 768w\" sizes=\"auto, (max-width: 960px) 100vw, 960px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns has-white-background-color has-background is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"960\" height=\"600\" src=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/04\/r1-konstruktion-02-klinger-kempchen.jpg\" alt=\"Konstruktion 3\" class=\"wp-image-16054\" srcset=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/04\/r1-konstruktion-02-klinger-kempchen.jpg 960w, https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/04\/r1-konstruktion-02-klinger-kempchen-768x480.jpg 768w\" sizes=\"auto, (max-width: 960px) 100vw, 960px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<h3 class=\"wp-block-heading h2\">The construction and <br>design of sealed connections<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>with gaskets at the main power connection<\/li>\n\n\n\n<li>with gaskets within metal to metal contact types<\/li>\n\n\n\n<li>flange joints on heat exchangers<\/li>\n\n\n\n<li>flange joints with clamped tubesheets<\/li>\n\n\n\n<li>with metal gaskets such as double-cone gaskets, weld-ring gaskets, ring-joint or lens gaskets<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns has-white-background-color has-background is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<h3 class=\"wp-block-heading h2\">Calculations for<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>sealed connections in accordance to DIN EN 1591-1<\/li>\n\n\n\n<li>sealed connections in accordance to DIN EN 13445 and DIN EN 13480<\/li>\n\n\n\n<li>sealed connections in accordance to KTA 3211.2 (metal to metal contact type)<\/li>\n\n\n\n<li>sealed connections in accordance according to ASME Section 8 Division I and Division II<\/li>\n\n\n\n<li>sealed connections in accordance to the KEMPCHEN calculation rules for rectangular flange joints<\/li>\n\n\n\n<li>sealed connections in accordance to the KEMPCHEN calculation rules for weld ring flange joints<\/li>\n\n\n\n<li>tightening torques for assembling the flange joints<\/li>\n\n\n\n<li>leak tightness certificates considering IPPC, TA Luft \/ VDI 2290<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"960\" height=\"600\" src=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/04\/r1-konstruktion-03-klinger-kempchen.jpg\" alt=\"Konstruktion 3\" class=\"wp-image-16056\" srcset=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/04\/r1-konstruktion-03-klinger-kempchen.jpg 960w, https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/04\/r1-konstruktion-03-klinger-kempchen-768x480.jpg 768w\" sizes=\"auto, (max-width: 960px) 100vw, 960px\" \/><\/figure>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>DESIGNING SEALED CONNECTIONS AND SPECIAL GASKETS Experience and knowledge of seals and sealing materials The designing, construction, calculation and specifications of gaskets and sealed connections require a great deal of experience and knowledge about how gaskets and sealing materials behave under various operating conditions. The mere application of well-known guidelines such as ASME, DIN EN [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":16049,"parent":17263,"menu_order":1,"comment_status":"closed","ping_status":"closed","template":"page-templates\/somos.php","meta":{"advgb_blocks_editor_width":"","advgb_blocks_columns_visual_guide":"","iawp_total_views":9,"footnotes":""},"class_list":["post-17298","page","type-page","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Designing sealed connections<\/title>\n<meta name=\"description\" content=\"The design, construction, calculation and specification of seals and sealing joints requires a lot of experience and knowledge.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.klinger-kempchen.de\/engineering\/engineering-services\/auslegung-dichtverbindungen\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Designing sealed connections\" \/>\n<meta property=\"og:description\" content=\"The design, construction, calculation and specification of seals and sealing joints requires a lot of experience and knowledge.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.klinger-kempchen.de\/engineering\/engineering-services\/auslegung-dichtverbindungen\/\" \/>\n<meta property=\"og:site_name\" content=\"KLINGER Kempchen\" \/>\n<meta property=\"article:modified_time\" content=\"2024-03-11T10:49:12+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/04\/Dichtverbindungen.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1400\" \/>\n\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Designing sealed connections","description":"The design, construction, calculation and specification of seals and sealing joints requires a lot of experience and knowledge.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.klinger-kempchen.de\/engineering\/engineering-services\/auslegung-dichtverbindungen\/","og_locale":"en_US","og_type":"article","og_title":"Designing sealed connections","og_description":"The design, construction, calculation and specification of seals and sealing joints requires a lot of experience and knowledge.","og_url":"https:\/\/www.klinger-kempchen.de\/engineering\/engineering-services\/auslegung-dichtverbindungen\/","og_site_name":"KLINGER Kempchen","article_modified_time":"2024-03-11T10:49:12+00:00","og_image":[{"width":1400,"height":350,"url":"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/04\/Dichtverbindungen.jpg","type":"image\/jpeg"}],"twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.klinger-kempchen.de\/engineering\/engineering-services\/auslegung-dichtverbindungen\/","url":"https:\/\/www.klinger-kempchen.de\/engineering\/engineering-services\/auslegung-dichtverbindungen\/","name":"Designing sealed connections","isPartOf":{"@id":"https:\/\/www.klinger-kempchen.de\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.klinger-kempchen.de\/engineering\/engineering-services\/auslegung-dichtverbindungen\/#primaryimage"},"image":{"@id":"https:\/\/www.klinger-kempchen.de\/engineering\/engineering-services\/auslegung-dichtverbindungen\/#primaryimage"},"thumbnailUrl":"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/04\/Dichtverbindungen.jpg","datePublished":"2023-06-27T12:11:23+00:00","dateModified":"2024-03-11T10:49:12+00:00","description":"The design, construction, calculation and specification of seals and sealing joints requires a lot of experience and knowledge.","breadcrumb":{"@id":"https:\/\/www.klinger-kempchen.de\/engineering\/engineering-services\/auslegung-dichtverbindungen\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.klinger-kempchen.de\/engineering\/engineering-services\/auslegung-dichtverbindungen\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.klinger-kempchen.de\/engineering\/engineering-services\/auslegung-dichtverbindungen\/#primaryimage","url":"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/04\/Dichtverbindungen.jpg","contentUrl":"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/04\/Dichtverbindungen.jpg","width":1400,"height":350,"caption":"Dichtverbindungen und Sonderdichtungen"},{"@type":"BreadcrumbList","@id":"https:\/\/www.klinger-kempchen.de\/engineering\/engineering-services\/auslegung-dichtverbindungen\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.klinger-kempchen.de\/en\/"},{"@type":"ListItem","position":2,"name":"Engineering","item":"https:\/\/www.klinger-kempchen.de\/en\/engineering\/"},{"@type":"ListItem","position":3,"name":"Engineering Services","item":"https:\/\/www.klinger-kempchen.de\/en\/engineering\/engineering-services\/"},{"@type":"ListItem","position":4,"name":"Designing sealed connections"}]},{"@type":"WebSite","@id":"https:\/\/www.klinger-kempchen.de\/#website","url":"https:\/\/www.klinger-kempchen.de\/","name":"KLINGER Kempchen","description":"KLINGER Kempchen","publisher":{"@id":"https:\/\/www.klinger-kempchen.de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.klinger-kempchen.de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.klinger-kempchen.de\/#organization","name":"KLINGER-Kempchen","url":"https:\/\/www.klinger-kempchen.de\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.klinger-kempchen.de\/#\/schema\/logo\/image\/","url":"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/06\/cropped-Klinger-Kempchen-Logo.png","contentUrl":"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/06\/cropped-Klinger-Kempchen-Logo.png","width":512,"height":512,"caption":"KLINGER-Kempchen"},"image":{"@id":"https:\/\/www.klinger-kempchen.de\/#\/schema\/logo\/image\/"}}]}},"coauthors":[],"author_meta":{"author_link":"https:\/\/www.klinger-kempchen.de\/en\/author\/administrador\/","display_name":"administrador"},"relative_dates":{"created":"Posted 3 years ago","modified":"Updated 2 years ago"},"absolute_dates":{"created":"Posted on 27 June 2023","modified":"Updated on 11 March 2024"},"absolute_dates_time":{"created":"Posted on 27 June 2023 14:11","modified":"Updated on 11 March 2024 11:49"},"featured_img_caption":"","featured_img":"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/04\/Dichtverbindungen.jpg","series_order":"","_links":{"self":[{"href":"https:\/\/www.klinger-kempchen.de\/en\/wp-json\/wp\/v2\/pages\/17298","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.klinger-kempchen.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.klinger-kempchen.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.klinger-kempchen.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.klinger-kempchen.de\/en\/wp-json\/wp\/v2\/comments?post=17298"}],"version-history":[{"count":0,"href":"https:\/\/www.klinger-kempchen.de\/en\/wp-json\/wp\/v2\/pages\/17298\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.klinger-kempchen.de\/en\/wp-json\/wp\/v2\/pages\/17263"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.klinger-kempchen.de\/en\/wp-json\/wp\/v2\/media\/16049"}],"wp:attachment":[{"href":"https:\/\/www.klinger-kempchen.de\/en\/wp-json\/wp\/v2\/media?parent=17298"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}