{"id":17343,"date":"2023-06-27T16:07:48","date_gmt":"2023-06-27T14:07:48","guid":{"rendered":"https:\/\/www.klinger-kempchen.de\/?page_id=17343"},"modified":"2024-03-11T12:07:53","modified_gmt":"2024-03-11T11:07:53","slug":"damage-and-incident-investigations","status":"publish","type":"page","link":"https:\/\/www.klinger-kempchen.de\/en\/engineering\/damage-investigation\/damage-and-incident-investigations\/","title":{"rendered":"Damage and incident investigations"},"content":{"rendered":"\n<h1 class=\"wp-block-heading h3\">DAMAGE AND INCIDENT INVESTIGATIONS<\/h1>\n\n\n\n<h2 class=\"wp-block-heading\">Systematic measures to identify causes<\/h2>\n\n\n\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"695\" height=\"958\" src=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/06\/kempchen_schadensanalyse_en.png\" alt=\"kempchen_schadensanalyse_en\" class=\"wp-image-17345 size-full\"\/><\/figure><div class=\"wp-block-media-text__content\">\n<p>In spite of careful construction, high-quality gaskets and an increasing assembly quality, and even when complying with the prescribed mode of operation, it is not always possible to prevent flange joints from failing. The well-known guidelines in particular have a few weaknesses.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile has-background\" style=\"background-color:#e8f3fa\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"960\" height=\"600\" src=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/06\/r10-0-01-klinger-engineering.jpg\" alt=\"\" class=\"wp-image-16763 size-full\" srcset=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/06\/r10-0-01-klinger-engineering.jpg 960w, https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/06\/r10-0-01-klinger-engineering-768x480.jpg 768w\" sizes=\"auto, (max-width: 960px) 100vw, 960px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p>These leaky flange joints often result in a massive economic loss due to the undesired leakage of media and the production down-time which follows in most cases.&nbsp;<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-media-text alignwide has-media-on-the-right is-stacked-on-mobile has-background\" style=\"background-color:#e8f3fa\"><div class=\"wp-block-media-text__content\">\n<p>The damage also mainly leads to a considerable repair expense with relatively high costs for maintaining and cleaning the area around the leakage. Here, it is important to introduce systematic measures for identifying the cause and to clarify all the circumstances in order to identify the causes of the leak.<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"960\" height=\"600\" src=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/06\/r10-0-02-klinger-engineering.jpg\" alt=\"\" class=\"wp-image-16767 size-full\" srcset=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/06\/r10-0-02-klinger-engineering.jpg 960w, https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/06\/r10-0-02-klinger-engineering-768x480.jpg 768w\" sizes=\"auto, (max-width: 960px) 100vw, 960px\" \/><\/figure><\/div>\n\n\n\n<div class=\"wp-block-media-text alignwide is-stacked-on-mobile has-background\" style=\"background-color:#e8f3fa\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"960\" height=\"600\" src=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/06\/r10-0-03-klinger-engineering.jpg\" alt=\"\" class=\"wp-image-16769 size-full\" srcset=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/06\/r10-0-03-klinger-engineering.jpg 960w, https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/06\/r10-0-03-klinger-engineering-768x480.jpg 768w\" sizes=\"auto, (max-width: 960px) 100vw, 960px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p>Corrective measures can only be introduced in a targeted manner if the cause of damage has been clarified by way of the corresponding investigations. The same or similar undesired incidents can be eliminated safely in the future.<\/p>\n<\/div><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Final investigation report<\/h2>\n\n\n\n<p>At the end, we will prepare an investigation report together with you, which states the direct causes of the leakage. All investigations are subject to the most stringent confidentiality.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-background wp-element-button\" href=\"https:\/\/www.klinger-kempchen.de\/engineering\/laboratory-services\/praktische-schadensanalyse\/\" style=\"background-color:#006fb0\">Practical damage analysis \u00bb<\/a><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>DAMAGE AND INCIDENT INVESTIGATIONS Systematic measures to identify causes In spite of careful construction, high-quality gaskets and an increasing assembly quality, and even when complying with the prescribed mode of operation, it is not always possible to prevent flange joints from failing. The well-known guidelines in particular have a few weaknesses. These leaky flange joints [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":16755,"parent":17268,"menu_order":1,"comment_status":"closed","ping_status":"closed","template":"page-templates\/somos.php","meta":{"advgb_blocks_editor_width":"","advgb_blocks_columns_visual_guide":"","iawp_total_views":15,"footnotes":""},"class_list":["post-17343","page","type-page","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Damage and incident investigations<\/title>\n<meta name=\"description\" content=\"Despite careful design, high quality gaskets, it is not always possible to avoid the failure of flange connections.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.klinger-kempchen.de\/engineering\/damage-investigation\/schadens-und-ereignisuntersuchungen\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Damage and incident investigations\" \/>\n<meta property=\"og:description\" content=\"Despite careful design, high quality gaskets, it is not always possible to avoid the failure of flange connections.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.klinger-kempchen.de\/engineering\/damage-investigation\/schadens-und-ereignisuntersuchungen\/\" \/>\n<meta property=\"og:site_name\" content=\"KLINGER Kempchen\" \/>\n<meta property=\"article:modified_time\" content=\"2024-03-11T11:07:53+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/06\/schaden-klinger-engineering.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1400\" \/>\n\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Damage and incident investigations","description":"Despite careful design, high quality gaskets, it is not always possible to avoid the failure of flange connections.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.klinger-kempchen.de\/engineering\/damage-investigation\/schadens-und-ereignisuntersuchungen\/","og_locale":"en_US","og_type":"article","og_title":"Damage and incident investigations","og_description":"Despite careful design, high quality gaskets, it is not always possible to avoid the failure of flange connections.","og_url":"https:\/\/www.klinger-kempchen.de\/engineering\/damage-investigation\/schadens-und-ereignisuntersuchungen\/","og_site_name":"KLINGER Kempchen","article_modified_time":"2024-03-11T11:07:53+00:00","og_image":[{"width":1400,"height":350,"url":"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/06\/schaden-klinger-engineering.jpg","type":"image\/jpeg"}],"twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.klinger-kempchen.de\/engineering\/damage-investigation\/schadens-und-ereignisuntersuchungen\/","url":"https:\/\/www.klinger-kempchen.de\/engineering\/damage-investigation\/schadens-und-ereignisuntersuchungen\/","name":"Damage and incident investigations","isPartOf":{"@id":"https:\/\/www.klinger-kempchen.de\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.klinger-kempchen.de\/engineering\/damage-investigation\/schadens-und-ereignisuntersuchungen\/#primaryimage"},"image":{"@id":"https:\/\/www.klinger-kempchen.de\/engineering\/damage-investigation\/schadens-und-ereignisuntersuchungen\/#primaryimage"},"thumbnailUrl":"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/06\/schaden-klinger-engineering.jpg","datePublished":"2023-06-27T14:07:48+00:00","dateModified":"2024-03-11T11:07:53+00:00","description":"Despite careful design, high quality gaskets, it is not always possible to avoid the failure of flange connections.","breadcrumb":{"@id":"https:\/\/www.klinger-kempchen.de\/engineering\/damage-investigation\/schadens-und-ereignisuntersuchungen\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.klinger-kempchen.de\/engineering\/damage-investigation\/schadens-und-ereignisuntersuchungen\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.klinger-kempchen.de\/engineering\/damage-investigation\/schadens-und-ereignisuntersuchungen\/#primaryimage","url":"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/06\/schaden-klinger-engineering.jpg","contentUrl":"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/06\/schaden-klinger-engineering.jpg","width":1400,"height":350,"caption":"schaden-klinger-engineering"},{"@type":"BreadcrumbList","@id":"https:\/\/www.klinger-kempchen.de\/engineering\/damage-investigation\/schadens-und-ereignisuntersuchungen\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.klinger-kempchen.de\/en\/"},{"@type":"ListItem","position":2,"name":"Engineering","item":"https:\/\/www.klinger-kempchen.de\/en\/engineering\/"},{"@type":"ListItem","position":3,"name":"Damage Investigation","item":"https:\/\/www.klinger-kempchen.de\/en\/engineering\/damage-investigation\/"},{"@type":"ListItem","position":4,"name":"Damage and incident investigations"}]},{"@type":"WebSite","@id":"https:\/\/www.klinger-kempchen.de\/#website","url":"https:\/\/www.klinger-kempchen.de\/","name":"KLINGER Kempchen","description":"KLINGER Kempchen","publisher":{"@id":"https:\/\/www.klinger-kempchen.de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.klinger-kempchen.de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.klinger-kempchen.de\/#organization","name":"KLINGER-Kempchen","url":"https:\/\/www.klinger-kempchen.de\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.klinger-kempchen.de\/#\/schema\/logo\/image\/","url":"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/06\/cropped-Klinger-Kempchen-Logo.png","contentUrl":"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/06\/cropped-Klinger-Kempchen-Logo.png","width":512,"height":512,"caption":"KLINGER-Kempchen"},"image":{"@id":"https:\/\/www.klinger-kempchen.de\/#\/schema\/logo\/image\/"}}]}},"coauthors":[],"author_meta":{"author_link":"https:\/\/www.klinger-kempchen.de\/en\/author\/administrador\/","display_name":"administrador"},"relative_dates":{"created":"Posted 3 years ago","modified":"Updated 2 years ago"},"absolute_dates":{"created":"Posted on 27 June 2023","modified":"Updated on 11 March 2024"},"absolute_dates_time":{"created":"Posted on 27 June 2023 16:07","modified":"Updated on 11 March 2024 12:07"},"featured_img_caption":"","featured_img":"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2023\/06\/schaden-klinger-engineering.jpg","series_order":"","_links":{"self":[{"href":"https:\/\/www.klinger-kempchen.de\/en\/wp-json\/wp\/v2\/pages\/17343","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.klinger-kempchen.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.klinger-kempchen.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.klinger-kempchen.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.klinger-kempchen.de\/en\/wp-json\/wp\/v2\/comments?post=17343"}],"version-history":[{"count":0,"href":"https:\/\/www.klinger-kempchen.de\/en\/wp-json\/wp\/v2\/pages\/17343\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.klinger-kempchen.de\/en\/wp-json\/wp\/v2\/pages\/17268"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.klinger-kempchen.de\/en\/wp-json\/wp\/v2\/media\/16755"}],"wp:attachment":[{"href":"https:\/\/www.klinger-kempchen.de\/en\/wp-json\/wp\/v2\/media?parent=17343"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}