{"id":9110,"date":"2020-07-22T16:35:38","date_gmt":"2020-07-22T14:35:38","guid":{"rendered":"https:\/\/www.klinger-kempchen.de\/product\/spezielle-dichtungen\/"},"modified":"2026-04-09T12:21:52","modified_gmt":"2026-04-09T10:21:52","slug":"special-gaskets","status":"publish","type":"page","link":"https:\/\/www.klinger-kempchen.de\/en\/products\/special-gaskets\/","title":{"rendered":"Special Gaskets"},"content":{"rendered":"\n<h1 class=\"wp-block-heading h2\">SPECIAL GASKETS<\/h1>\n\n\n\n<p><strong><a href=\"#double-seal\">\u00bb DOUBLE SEALING SYSTEM<\/a><br><a href=\"#splatter\">\u00bb SPLATTER-SHIELD STRIPS<\/a><br>\u00bb<a href=\"#baffle\"> BAFFLE SEALS T4<\/a><br><a href=\"#kemstherm\">\u00bb KEMSTHERM<\/a><br><a href=\"#kemshape\">\u00bb KEMSHAPE<\/a><\/strong><\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" id=\"double-seal\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">DOUBLE SEALING SYSTEM<\/h2>\n\n\n\n<h3 class=\"wp-block-heading h4\">KHS \/ KNS with intermediate exhausting<\/h3>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p>Old and new plants constantly place greater demands on safety and reliability. This applies at certain sizes to bolted flange connections on apparatuses, valves and pipelines. For many years, sealing systems with intermediate exhaust\u00ading or certain areas of the chemical industry. The simplest example of this consists of two O-rings concentrically ar\u00adranged in grooves.<\/p>\n\n\n\n<p>Similar designs are problem-free, as long as the components to be sealed are inherently stable and retain their position relative to each other. The bolt load applied, the internal pressure, the temperature or even external forces and moments all cause the flanges to take on a certain angle to each other, and so large deformations in the area of the seal should be anticipated.<\/p>\n\n\n\n<h5 class=\"wp-block-heading\"><strong>Design and operation<\/strong><\/h5>\n\n\n\n<p>The use of some gaskets leads to noticeable difficulties if the gasket is not able to securely seal the flanges as they slant against each other. Therefore the problem is even more difficult when two concentrically aligned gaskets are used.<\/p>\n\n\n\n<p>If both gaskets are aligned as a main load seal or else if both are in off load contact, in each case significantly greater seal\u00ading recovery proportionate to the lever arms is required from a gasket than from other gaskets.<\/p>\n\n\n\n<p>In many cases it has proven preferable not to have the com\u00adponents so inherently stable, so that leaks can be avoided with the pressure applied or with large applications of force.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"646\" height=\"464\" src=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/08\/Double-Sealing-profile.png\" alt=\"\" class=\"wp-image-9250\"\/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<h4 class=\"wp-block-heading\">Downloads<\/h4>\n\n\n\n<p>Enclosed you will find downloads such as product documentation, product data sheet, safety information and gasket characteristics.<\/p>\n\n\n\n<p><img decoding=\"async\" src=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/07\/Download-icon-2.png\" alt=\"\"><a href=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/08\/136-139-DOUBLE-SEALING-SYSTEM.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Product documentation DOUBLE SEALING SYSTEM (pdf)<\/a><\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">SPLATTER-SHIELD STRIPS<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p>Dangerous, hot or pressurised media are transported through pipelines in many branches of industry. Wherever these pipe\u00adlines are connected to each other with bolted flanges, there is a danger that a leakage of the dangerous medium will occur, leading to an accident.<\/p>\n\n\n\n<p>This can involve acids or alkalis, high-pressure steam or boil\u00ading water, high-pressure hydraulic oil or heat-carrying oil, com\u00adpressed air or water, to name the most important sources of danger.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong><strong>Design and operation<\/strong><\/strong><\/h4>\n\n\n\n<p>Splatter-shield strips in Profile BWQ are made from 0.2 mm thick stainless steel strip of material 1.4541. They are corru\u00adgated at right angles to the length. When used with a flange connection, the corrugation along the strip creates many small openings to the outside.<\/p>\n\n\n\n<p>This means that the dangerous medium cannot stream out directly onto a person standing in front of the flange connec\u00adtion. Instead, the stream of acid, alkali or water will hit the interior of the splatter-shield strip and then flow at low pres\u00adsure through the opening.<\/p>\n\n\n\n<h3 class=\"wp-block-heading h4\">Downloads<\/h3>\n\n\n\n<p>Enclosed you will find downloads such as product documentation, product data sheet, safety information and gasket characteristics.<\/p>\n\n\n\n<p><img decoding=\"async\" src=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/07\/Download-icon-2.png\" alt=\"\"><a href=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/08\/140-141-SPLATTER-SHIEL-STRIPS.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Product documentation SPLATTER-SHIELD STRIPS (pdf)<\/a><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"646\" height=\"512\" src=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/07\/Spritzschutzband.jpg\" alt=\"Flansch mit Spritzschutz\" class=\"wp-image-7376\"\/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">BAFFLE SEALS T4<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p>Seal for sealing longitudinal baffles in high-performance heat exchangers.<\/p>\n\n\n\n<p>Baffle seal profile T4 is a full metal seal. It is generally made from 1.4571 steel for the lamellae supports and for the lamellas themselves. On request for larger these seals can also be produced from other spring-elastic steels or non-ferrous metals.<\/p>\n\n\n\n<p>We are able to produce precisely adapted separating plate gaskets for every heat exchanger. Particularly suitable for heat exchangers with large or small gaps, due to construction filters, refurbishment or warping.<\/p>\n\n\n\n<p>This seal plays an important role in effectively sealing the gap between the longitudinal baffle and the heat ex-changer shell in high-performance heat exchangers. In par-ticular, when there are small differences in temperature, even low short-circuit currents cause a significant power loss. This can largely be avoided by using the baffle seal T4. The T4 seal is easily assembled directly onto the longitudinal baffle.<br>No bolts are required to affix it. This means that there is no need to drill holes or to do any of the usual bolting work during assembly.<\/p>\n\n\n\n<h3 class=\"wp-block-heading h4\">Downloads<\/h3>\n\n\n\n<p>Enclosed you will find downloads such as product documentation, product data sheet, safety information and gasket characteristics.<\/p>\n\n\n\n<p><img decoding=\"async\" src=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/07\/Download-icon-2.png\" alt=\"\"><a href=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/08\/142-BAFFEL-SEALS-T4.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Product documentation BAFFLE SEALS T4 (pdf)<\/a><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"650\" height=\"518\" src=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/08\/Baffle-Seal.png\" alt=\"\" class=\"wp-image-9252\"\/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">KEMTHERM<\/h2>\n\n\n\n<h3 class=\"wp-block-heading h4\">Developed for your safety!<\/h3>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p>KemTherm is a static seal for standard and non-standard flange connections, with an integrated thermal element for very accurate measurement of the flow medium temperature.<\/p>\n\n\n\n<p>The measurement signal can be integrated and processed in all process control systems and can be used to control and regulate processes.<\/p>\n\n\n\n<p><strong>Function<\/strong><\/p>\n\n\n\n<p>KemTherm is available as a grooved gasket type B15T. A thermal element is integrated into the carrier core, which makes it possible to measure the temperature over the entire 360\u00b0 circumference. The temperatures are recorded and made available as averaged values.<\/p>\n\n\n\n<p><strong>APPLICATION<\/strong><\/p>\n\n\n\n<p>If the temperature is to be measured in a pipeline system, this can currently be done with the aid of a built-in sensor or a contact sensor. Both variants have specifi c disadvantages. An immersion sensor is extremely complex to install and disrupts the pipe flow.<\/p>\n\n\n\n<p>A contact sensor is very strongly dependent on the ambient conditions and delivers very imprecise measured values. KemTherm has none of these disadvantages.<\/p>\n\n\n\n<p>It is very easy to install at any point of the flange connection, and provides an accurate temperature reading and can be used up to an operating pressure of 160 bar and a maximum operating temperature of 400\u00b0C. The KemTherm gasket can be installed on flange connections with sealing surface shapes A and B according to DIN EN 1092, and shape RF according to DIN EN 1759.<\/p>\n\n\n\n<p>The dimensions of the gasket core do not comply with current standards, but are rather optimised specifically for improved temperature absorption. Overall seal height before installation and centering diameter corresponds to the standard seals of the standards DIN EN 1514 and DIN EN 10260.<\/p>\n\n\n\n<p><strong>ADVANTAGES<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The pipe flow is not affected<\/li>\n\n\n\n<li>Simple subsequent installation by changing the gasket<\/li>\n\n\n\n<li>No \u201ctrouble spots\u201d (potential leaks) appear along the pipe section<\/li>\n\n\n\n<li>Installation is possible at any flange connection<\/li>\n\n\n\n<li>KemTherm is weatherproof<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\">Downloads<\/h4>\n\n\n\n<p>Enclosed you will find downloads such as product documentation, product data sheet, safety information and gasket characteristics.<\/p>\n\n\n\n<p><img decoding=\"async\" src=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/07\/Download-icon-2.png\" alt=\"\"><a href=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/08\/072020_FLYER-KEMTHERM-UK.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Flyer KemTherm<\/a><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"KemTherm EN\" width=\"625\" height=\"352\" src=\"https:\/\/www.youtube.com\/embed\/pcQgxonngnM?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"900\" height=\"1260\" src=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/08\/KemTherm.jpg\" alt=\"\" class=\"wp-image-10232\" srcset=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/08\/KemTherm.jpg 900w, https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/08\/KemTherm-768x1075.jpg 768w, https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/08\/KemTherm-14x20.jpg 14w\" sizes=\"auto, (max-width: 900px) 100vw, 900px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">KEMSHAPE<\/h2>\n\n\n\n<h3 class=\"wp-block-heading h4\">Representation of sealing surface damage<\/h3>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<p><strong>Function<\/strong><\/p>\n\n\n\n<p>The impression material is prepared in equal parts from a Base and a Catalyst. When the two components<br>are mixed, a modelling compound similar to plasticine is produced, which is then applied to the<br>damaged areas of the sealing surface. When applying the impression material, make sure that the<br>entire area of the sealing surface is covered from the outside diameter of the sealing strip to the inside<br>diameter of the flange.<\/p>\n\n\n\n<p>When the impression material is pressed on, it produces a detailed 3-dimensional image of the<br>surface damage.<\/p>\n\n\n\n<p>After application and pressing, the impression material must harden for approx. 3 to 6 minutes and can then<br>be carefully removed. After detachment, the result can be directly assessed, macroscopically. All details are<br>clearly visible in the impression.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Downloads<\/h4>\n\n\n\n<p>Enclosed you will find downloads such as product documentation, product data sheet, safety information and gasket characteristics.<\/p>\n\n\n\n<p><img decoding=\"async\" src=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/07\/Download-icon-2.png\" alt=\"\"><a href=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/08\/FLYER_KEMSHAPE-UK.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Flyer KemShape (pdf)<\/a><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"KLINGER Kempchen KemShape  EN\" width=\"625\" height=\"352\" src=\"https:\/\/www.youtube.com\/embed\/7I-qBDkayrQ?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"900\" height=\"506\" src=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/08\/kemShape-1.jpg\" alt=\"Abformmasse f\u00fcr besch\u00e4digte Flansche\" class=\"wp-image-10239\" srcset=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/08\/kemShape-1.jpg 900w, https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/08\/kemShape-1-768x432.jpg 768w, https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/08\/kemShape-1-20x11.jpg 20w\" sizes=\"auto, (max-width: 900px) 100vw, 900px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p><\/p>\n\n\n\n<p>You can download our PDF request form here: <strong><a href=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2026\/02\/03_ENG_Request_data_sheet_form_R01_20260210_LH-.pdf\" type=\"link\" id=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2026\/03\/03_ENG_Request_data_sheet_form_R01_20260309_LH-.pdfds\/2026\/03\/03_ENG_Request_data_sheet_form_R01_20260309_LH-.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Download request form<\/a><\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>SPECIAL GASKETS \u00bb DOUBLE SEALING SYSTEM\u00bb SPLATTER-SHIELD STRIPS\u00bb BAFFLE SEALS T4\u00bb KEMSTHERM\u00bb KEMSHAPE DOUBLE SEALING SYSTEM KHS \/ KNS with intermediate exhausting Old and new plants constantly place greater demands on safety and reliability. This applies at certain sizes to bolted flange connections on apparatuses, valves and pipelines. For many years, sealing systems with intermediate [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":7534,"parent":1003,"menu_order":6,"comment_status":"closed","ping_status":"closed","template":"page-templates\/somos.php","meta":{"advgb_blocks_editor_width":"","advgb_blocks_columns_visual_guide":"","iawp_total_views":293,"footnotes":""},"class_list":["post-9110","page","type-page","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Special Gaskets - KLINGER Kempchen<\/title>\n<meta name=\"description\" content=\"Special seals: We offer optimal solutions for the special individual case. Our consulting engineers come to your factory.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.klinger-kempchen.de\/en\/products\/special-gaskets\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Special Gaskets - KLINGER Kempchen\" \/>\n<meta property=\"og:description\" content=\"Special seals: We offer optimal solutions for the special individual case. Our consulting engineers come to your factory.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.klinger-kempchen.de\/en\/products\/special-gaskets\/\" \/>\n<meta property=\"og:site_name\" content=\"KLINGER Kempchen\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-09T10:21:52+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/07\/Spezialdichtungen-titel.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1400\" \/>\n\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"9 minutes\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Special Gaskets - KLINGER Kempchen","description":"Special seals: We offer optimal solutions for the special individual case. Our consulting engineers come to your factory.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.klinger-kempchen.de\/en\/products\/special-gaskets\/","og_locale":"en_US","og_type":"article","og_title":"Special Gaskets - KLINGER Kempchen","og_description":"Special seals: We offer optimal solutions for the special individual case. Our consulting engineers come to your factory.","og_url":"https:\/\/www.klinger-kempchen.de\/en\/products\/special-gaskets\/","og_site_name":"KLINGER Kempchen","article_modified_time":"2026-04-09T10:21:52+00:00","og_image":[{"width":1400,"height":350,"url":"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/07\/Spezialdichtungen-titel.jpg","type":"image\/jpeg"}],"twitter_misc":{"Est. reading time":"9 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.klinger-kempchen.de\/en\/products\/special-gaskets\/","url":"https:\/\/www.klinger-kempchen.de\/en\/products\/special-gaskets\/","name":"Special Gaskets - KLINGER Kempchen","isPartOf":{"@id":"https:\/\/www.klinger-kempchen.de\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.klinger-kempchen.de\/en\/products\/special-gaskets\/#primaryimage"},"image":{"@id":"https:\/\/www.klinger-kempchen.de\/en\/products\/special-gaskets\/#primaryimage"},"thumbnailUrl":"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/07\/Spezialdichtungen-titel.jpg","datePublished":"2020-07-22T14:35:38+00:00","dateModified":"2026-04-09T10:21:52+00:00","description":"Special seals: We offer optimal solutions for the special individual case. Our consulting engineers come to your factory.","breadcrumb":{"@id":"https:\/\/www.klinger-kempchen.de\/en\/products\/special-gaskets\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.klinger-kempchen.de\/en\/products\/special-gaskets\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.klinger-kempchen.de\/en\/products\/special-gaskets\/#primaryimage","url":"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/07\/Spezialdichtungen-titel.jpg","contentUrl":"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/07\/Spezialdichtungen-titel.jpg","width":1400,"height":350,"caption":"Spezielle Dichtungen"},{"@type":"BreadcrumbList","@id":"https:\/\/www.klinger-kempchen.de\/en\/products\/special-gaskets\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.klinger-kempchen.de\/en\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/www.klinger-kempchen.de\/en\/products\/"},{"@type":"ListItem","position":3,"name":"Special Gaskets"}]},{"@type":"WebSite","@id":"https:\/\/www.klinger-kempchen.de\/#website","url":"https:\/\/www.klinger-kempchen.de\/","name":"KLINGER Kempchen","description":"KLINGER Kempchen","publisher":{"@id":"https:\/\/www.klinger-kempchen.de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.klinger-kempchen.de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.klinger-kempchen.de\/#organization","name":"KLINGER-Kempchen","url":"https:\/\/www.klinger-kempchen.de\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.klinger-kempchen.de\/#\/schema\/logo\/image\/","url":"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/06\/cropped-Klinger-Kempchen-Logo.png","contentUrl":"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/06\/cropped-Klinger-Kempchen-Logo.png","width":512,"height":512,"caption":"KLINGER-Kempchen"},"image":{"@id":"https:\/\/www.klinger-kempchen.de\/#\/schema\/logo\/image\/"}}]}},"coauthors":[],"author_meta":{"author_link":"https:\/\/www.klinger-kempchen.de\/en\/author\/administrador\/","display_name":"administrador"},"relative_dates":{"created":"Posted 6 years ago","modified":"Updated 2 weeks ago"},"absolute_dates":{"created":"Posted on 22 July 2020","modified":"Updated on 9 April 2026"},"absolute_dates_time":{"created":"Posted on 22 July 2020 16:35","modified":"Updated on 9 April 2026 12:21"},"featured_img_caption":"Spezielle Dichtungen","featured_img":"https:\/\/www.klinger-kempchen.de\/wp-content\/uploads\/2020\/07\/Spezialdichtungen-titel.jpg","series_order":"","_links":{"self":[{"href":"https:\/\/www.klinger-kempchen.de\/en\/wp-json\/wp\/v2\/pages\/9110","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.klinger-kempchen.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.klinger-kempchen.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.klinger-kempchen.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.klinger-kempchen.de\/en\/wp-json\/wp\/v2\/comments?post=9110"}],"version-history":[{"count":4,"href":"https:\/\/www.klinger-kempchen.de\/en\/wp-json\/wp\/v2\/pages\/9110\/revisions"}],"predecessor-version":[{"id":64668,"href":"https:\/\/www.klinger-kempchen.de\/en\/wp-json\/wp\/v2\/pages\/9110\/revisions\/64668"}],"up":[{"embeddable":true,"href":"https:\/\/www.klinger-kempchen.de\/en\/wp-json\/wp\/v2\/pages\/1003"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.klinger-kempchen.de\/en\/wp-json\/wp\/v2\/media\/7534"}],"wp:attachment":[{"href":"https:\/\/www.klinger-kempchen.de\/en\/wp-json\/wp\/v2\/media?parent=9110"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}